Sanitary Hygienic Tank Bottom Solenoid Diaphragm Valve

Model:
JOV-DHPP02-22
Brand:
J&O
Material:
SS316L
Connection:
Clamped
Gasket:
EPDM+PTFE/EPDM
Working Temperature:
-20°~+120°
Working Pressure:
0-10Bar
Operation:
Pneumatic
Payment:
T/T, L/C, Western Union

A sanitary diaphragm valve isolates process streams from operating drive mechanisms through an elastomeric barrier compressed against a raised weir. This geometry eliminates dynamic shaft seals, satisfies ASME BPE drainability mandates, and guarantees hermetic shutoff during automated Clean-in-Place (CIP) and Steam-in-Place (SIP) routines.

Actuator Thrust Calibration and Diaphragm Seat Protection

Automated processing loops subject hygienic diaphragm valves to rapid cycling under line backpressures. Pneumatic piston actuators generate controlled downward thrust to close against fluid pressures up to 10 bar.

Factory-calibrated internal springs balance sealing force across elastomeric membranes without cutting fluoropolymer surfaces during thermal sterilization sequences.

Pilot Air Distribution and Rapid Signal Transmission

Precision timing requires dedicated pilot airflow control near the main actuator chamber. Coupling a direct-mount sanitary solenoid valve delivers immediate pneumatic pressurization to the internal piston.

Fast exhaust venting prevents delayed valve closure, minimizing line water hammer and protecting downstream filtration media from sudden pressure spikes.

Pneumatic Operator Sizing and Air Consumption Parameters

Selecting correct piston dimensions maintains rapid travel speeds while minimizing compressed air draw:

Piston Cylinder Bore Control Air Pressure Stroke Transit Speed Actuator Operating Air Volume
50 mm Actuator 4.5 to 6.0 bar 0.4 seconds 0.15 Normal Liters
80 mm Actuator 5.0 to 6.5 bar 0.8 seconds 0.45 Normal Liters
100 mm Actuator 5.5 to 7.0 bar 1.2 seconds 0.95 Normal Liters

Matched sizing prevents actuator sluggishness during automated recipe changes across continuous processing setups.

Vessel Clearance and Contaminant Elimination

Discharging preparation vessels requires unobstructed gravity drainage across batch sequences. Welded directly to lower dished ends, a tank bottom diaphragm valve mounts flush with vessel contours.

This placement eliminates stagnant dead zones between tank outlets and closure seats, facilitating swift clearing during sterile fluid recovery.

Technical Data

Valve Body Material: SS316L
Seal Material: EPDM+PTFE/ EPDM
Mex working pressure: 10Bar
Max. Working Temperature: 120 degree C
Availably size: 1"-4", DN25-DN100
Availably connection: Clamp, weld
Availably standard: 3A/DIN/SMS/RJT/ISO/IDF
Operated: Pneumatic

Product Pictures